LT-100-50
Information
- Low voltage shock capacitor, high current, high efficiency, low water cooling.
- The transformer has an insulation rating of more than 3000AC, good quality, and no breakdown.
- The range of the coil is wide, and it can work in both length and length.
Specification
Model | LT-100-50 |
Input voltage |
380VAC(±15%) 3 Phase 380VAC(±15%) 3 Phase |
Input power | 100KVA |
Oscillation frequency | 25K ~ 70KHz |
Output voltage | 1200VOLT MAX |
Cooling water flow | 50L/MIN, 2.5Kg-cm²(35psi) |
Host protection module |
DC overcurrent protection
AC overcurrent protection
Phase loss protection
Input overvoltage protection
Output overvoltage protection
Underwater protection
Over temperature protection
|
Lead-out line |
Start and stop signal
Machine running signal
DC 0~5V (4-20mA) power control (optional), RS485 power
Control (optional)
|
Estimated weight |
Host weight: 100KG
Extension weight: 40KG
|
Estimated size |
Host size: 110H/70W/45D
Standard capacitor size: 55H/30W/60D
|
Optional
DC 0~5V (4-20mA) power control
Other
With the heating effect of large coil and small workpiece, it can still reach the temperature of forging or gasification and evaporation.
Thin plate forging above 3MM, evaporation coating production line, heat shrinking, stainless steel cylinder tempering, laboratory vacuum melting furnace
The host extension line can reach 6 meters to 10 meters (need to be customized)