LT-100-120
Information
Made in TaiwanThe panel function has a nine-stage heating mode, and each stage of heating power and time can be individually set and stored.
Specification
Model | LT-100-120 |
Input voltage | 380VAC (± 15%) three-phase |
Input power | 100KVA |
Oscillation frequency | 30K~120KHz |
Output voltage | AC 50VOLT max |
Cooling water flow | 10L/MIN, 2.5Kg-cm² (35psi) |
Host protection module |
DC overcurrent protection AC overcurrent protection Under-phase protection Input overvoltage protection Output overvoltage protection Underwater protection Over temperature protection |
Lead-out line |
Start stop signal Machine running signal DC 0~5V power control (optional) RS-232 (FOR PLC, PDA, COMPUTER..) power control (optional) |
Estimated weight |
Host: Heating head: |
Estimated size |
Host: Heating head: |
Optional
Infrared non-contact temperature probe: The temperature range is shown in the table below. There are four probes available.- 250 °C -800 °C
- 400 °C -1200 °C
- 700 °C -1600 °C
- 1000 °C -2000 °C
Digital temperature controller: 200mS sampling speed, PID temperature control, automatic logic calculation and optional RS-232 digital interface.